Ammunition and explosives safety standards herein shall be considered minimum and greater protection shall be afforded when practicable. They apply. The Chairman, Department of Defense Explosives Safety Board (DDESB), is today announcing several changes to DoD STD, dated 5. The Department of Defense Explosives Safety Board (DDESB) is announcing Board-approved changes to DoD STD, dated August.

Author: Magal Meztir
Country: El Salvador
Language: English (Spanish)
Genre: Music
Published (Last): 28 November 2015
Pages: 470
PDF File Size: 10.38 Mb
ePub File Size: 13.24 Mb
ISBN: 184-9-46685-490-4
Downloads: 73520
Price: Free* [*Free Regsitration Required]
Uploader: Fekree

Fragments resulting from explosions create the greatest danger to people as fragments may travel several hundred meters and still have velocities that could be lethal or injurious. Blast resistant trash receptacles that meet the requirements of Specification E when subjected to internal explosions equal to or less than the force protection rating contain horizontal primary fragments and do not produce secondary fragments.

For example, special security concerns 6055.9std high value facilities or high pedestrian count venues will require guidance concerning the deployment of blast resistant trash receptacles from security personnel familiar with that facility.

  DIEGO ORTIZ RECERCADA PRIMERA PDF

DOD x9-STD CHG-2 STD AMMUNITION SAFETY

The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. The selection of deployment locations impacts both the mitigation of the effects of an explosion occurring within one as well as the convenience of using the receptacles. Historical Version s – view previous versions of standard.

The ddo in this guide are intended to mitigate the damaging effects of fragmentation and overpressure in crowded places.

It is not in general intended to provide guidance on the protection of structures in the vicinity of where the blast resistant trash receptacles are deployed. ICS Number Code Link to Active This link will always route to the current Active version of the standard. This effect may cause burns to people caught within or near to the fireball.

Combining values from the two systems may result in non-conformance with the standard.

  JBL CONTROL 25T PDF

It is important, therefore, that blast resistant trash receptacles are not placed near combustible materials. Every facility or venue has unique features associated with factors such as demographics, location, and functions.

DOD 6055.9-STD, DEPARTMENT OF DEFENSE: AMMUNITION AND EXPLOSIVES SAFETY STANDARDS (JUL 1999)

Also, it is possible that the heat output from an explosion may cause nearby combustible material to ignite. It is the responsibility of 605.9-std user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are 6055.9-sstd provided as part of the standard.

Trash receptacles in crowded places have been, and continue to be, an attractive repository for explosives.