Kingspan Therma TF70 Floorboard; high performance insulation for floors with a continuous thermal performance, lasting a constructions life cycle. Kingspan TF70, TW55 and TP10 are readily available in the following product thicknesses 20mm, 25mm, 30mm, 40mm, 50mm, 60mm, 70mm, 75mm, 80mm. Thermafloor TF70 is a high performance, fibre free, rigid thermoset insulation core faced on both sides with a low emissivity composite foil facing which is used .

Author: Arashibei Faurg
Country: Comoros
Language: English (Spanish)
Genre: Travel
Published (Last): 7 April 2010
Pages: 73
PDF File Size: 9.31 Mb
ePub File Size: 7.38 Mb
ISBN: 601-6-72270-443-3
Downloads: 85566
Price: Free* [*Free Regsitration Required]
Uploader: Tusida

The insulation boards should always be loose—laid break—bonded, with joints lightly butted.

Kingspan TF70 Thermafloor PIR for floating and suspended ground floors

In order to ensure insulation boards are flush with the top surface of the joists, they should be supported on minimum 25 kinggspan x 25 mm treated softwood timber battens, proprietary galvanised steel saddle clips, or galvanised nails partially driven into the side of the joists. Measure the distance between the joists prior to cutting the boards as spacings can vary. Do you need help or advice on a project?

Click to download in a separate browser window. Kingspan TF70 20mm, 15 x 1.

50mm Thermafloor TF70 PIR Insulation Board Kingspan

The subsequent installation of the concrete slab and screed or other flooring material is carried out in a manner similar to that for an un—insulated floor. Kingspan Thermafloor TF70 is not kingspam for installation directly over timber joists.

Timber floor boards e. Kingspan Insulation Ltd For queries relating to insulation boards, cavity closers or membranes. Any narrow gaps between battens and perimeter wall should be insulated by specially cut pieces of board.

This may affect the rates; we will of course discuss possible solutions with you before proceeding and will do our best to keep additional costs down. Use sand and cement screed laid to a minimum thickness of 65 mm for domestic construction and 75 mm elsewhere.

Installation Below a Kingsoan Timber Floor Concrete slabs should be allowed to dry out fully prior to the installation of Kingspan Thermafloor TF70 average 1 day per mm of slab thickness. Product Kingdpan The Front Facings TF70 is faced on both sides with a low emissivity composite foil facing which is highly resistant to the transmission of water vapour.

  FISIOPATOLOGIA DE ASPIRACION DE MECONIO PDF

We use cookies on our website www. The insulation core is not resistant to some solvent—based adhesives systems, particularly those containing methyl ethyl ketone. TF70 is faced on both sides with a low emissivity composite foil facing which is highly resistant to the transmission of water vapour.

Common applications for this product include Select products below to see pricing structure Use product tick-boxes to select required products Add to Basket Kingspan TF70 20mm, 15 x 1. Unfortunately, further to the recent supply challenges with PIR and Phenolic insulation boards from Celotex, Kingspan, Ecotherm and Recticel, available stock of these tff70 will vary throughout the country. Installation Between Battens under a Timber Floor Concrete slabs should be allowed to dry out fully prior to the installation of the insulation boards average 1 day per mm of slab thickness.

To find out more about the cookies we use, or to change your cookie preferences i. Architects Consarc Conservation in Belfast worked closely with the main contractor Woodvale Construction Company to bring life back to this wonderful building which has been vacant since Damaged boards or boards that have been in contact with harsh solvents or acids should not be used.

Manufactured to order are the following thicknesses 45mm, 55mm, 65mm, 85mm, mm, mm, mm, mm and mm. Adhesives containing such solvents should not be used in association with this product. Kingspan K3 K3 superior performance phenolic boards for use in ground floors, or on supported or suspended concrete and timber floors. TF70, when subjected to British Standard fire tests, achieves the results given below. Please observe the ‘Star Rating’ indicators to assess availability.

Kinsgpan of test to determine the classification of the surface spread of flame of products Result – Class 1 rating. Kingspan TF70, TW55 and TP10 are readily available in the following product thicknesses 20mm, 25mm, 30mm, 40mm, 50mm, 60mm, 70mm, 75mm, 80mm, 90mm, mm, mm, mm and mm. Kingspan TF70 50mm, 6 x 1. All board joints should be tightly butted.

Concrete slabs should be allowed to dry out fully prior to the installation of Kingspan Thermafloor TF70 average 1 day kingsppan mm of slab thickness. Side—nail 25 mm x 25 mm timber battens to the joists or partially drive galvanised nails into the side of the joists in the appropriate position to hold the boards in place.

  15JC 18JI PDF

If two layers of insulation are required, they should be horizontally offset relative to each other so that, as far as possible, the board joints in the two adjacent layers do coincide with each other.

Kingspan TF70 25mm, 12 x 1. Once the timber floor boards have been laid, temporary wedges should be inserted between the ikngspan and the floor, to maintain tight joints, until the adhesive has set. Test – BS —3: If you do not click “Accept and close” but continue to use this website: A thin sand blinding may be used to achieve a continuous level surface free from projections over rolled hardcore.

Product brochure Useful links Case studies.

A strip of the insulation board minimum 20mm thick should be placed vertically around the perimeter of the floor slab in order to prevent cold bridging. Kingspan TF70 30mm, 10 x 1. It used to insulate solid concrete and suspended timber ground floors, and has a thermal conductivity of 0. Kingspn performance floor insulation Thermafloor TF70 is a high performance rigid thermoset polyisocyanurate PIR insulation board for use in solid concrete and suspended ground floors.

Thermafloor® TF70

Before the timber floor boards are interlocked, apply a continuous bead of waterproof wood grade PVA adhesive to the top and bottom of the tongue and groove joints.

The top of the strip of insulation board should be level with the top of the kingspam screed and the bottom should be level with the bottom of the horizontal floor insulation, and closely butted up to it.

The membrane should be brought up the surrounding foundation walls until it is sufficiently above the height of the wall DPC so that it wil connect with or form the DPC. The most popular board sizes may be available from stock. Its durability depends on the supporting structure and tf0 conditions of its use.